VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration

    Buy cheap VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration from wholesalers
     
    Buy cheap VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration from wholesalers
    • Buy cheap VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration from wholesalers
    • Buy cheap VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration from wholesalers
    • Buy cheap VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration from wholesalers

    VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration

    Ask Lasest Price
    Brand Name : VICTOR
    Model Number : VICTOR 15+
    Certification : CE
    Price : USD350/pc
    Payment Terms : T/T, Western Union, L/C, Paypal
    Supply Ability : 1000pcs available
    Delivery Time : 5 to 30 days
    • Product Details
    • Company Profile

    VICTOR15+ Multifunction Process Calibrator Handheld Battery-Operated Instrument for Measuring and Sourcing Parameters with Pressure Calibration

    VICTOR 15+ V/mA Calibrator current calibrator handheld calibrator
    V/mA/Pressure Calibrator

    • Introduction

    The voltage/current/pressure calibrator (the calibrator in the following) is a handheld, battery-operated instrument that measures and sources electrical and physical parameters.
    Features:
    Measure: DC-voltage, DC-current, frequency and continuity
    Source: DC-voltage, DC-current, simulation transmitter, frequency and pulse

    Pressure: measuring pressure, Calibrating pressure-voltage transmitter, Calibrating 2wire pressure transmitter, Calibrating pressure switch;
    Others features:

    • Manual step source and auto -step and sweeping –step source
    • Measurement/source mA% display
    • Measurement wave-filter function
    • Measurement manual-holding function
    • Pressure source auto-holding function

    Specifications
    General Specifications for measure
    These specifications assume:

    • A 1-year calibration cycle
    • An operating temperature of 18℃ to 28℃
    • Relative humidity of 35% to 70% (non_condensing)

    Accuracy is expressed as ± (percentage of reading + percentage of range).

    F FunctionReferenceRangeResolutionAccuracyRemark
    DCV200mV

    -20.00mV~
    220.00mV

    10μV0.02+0.02Input Resistance: 100MΩ
    5V

    -0.5000V~
    5.5000V

    0.1mV0.02+0.01Input Resistance: 1MΩ
    50V

    -5.000V~
    55.000V

    1mV0.03+0.01
    DCmA50mA

    -4.000mA~
    55.000mA

    1μA0.02+0.01Input Resistance: 5Ω
    FREQ500Hz3Hz~500.00Hz0.01Hz±2digit

    Input Impedance:100 kΩ at least;
    Sensitivity:3Vp-p minimum;
    Duty Cycle: 50%.

    5KHz

    3Hz~
    5.0000KHz

    0.1Hz
    50KHz3Hz~50.000KHz1Hz
    *CONT.≤250Ω soundOPEN/CLOSEOpen voltage: 2.5V


    General Specifications for Source

    FunctionReferenceRangeResolutionAccuracyRemark

    DCV

    1000mV-100.000mV~1100.000mV10μV0.02+0.01Maximum output current: 2mA
    10V-1.0000V~11.0000V0.1mV0.02+0.01Maximum output current: 5mA

    DCA

    20mA0.000mA~22.000mA1μA0.02+0.02

    External supply for simulate mA: 5V–28V
    Maximum load 1KΩ at 20mA

    FREQ100Hz1.00Hz~110.00Hz0.01Hz±2 count

    Output voltage: 1~11 Vp-p (zero base waveform);
    Amplitude accuracy: ±(10% +0.5V);
    Maximum load: >100 KΩ;
    Duty Cycle: 50%.

    1KHz0.100kHz~1.100KHz1Hz
    10KHz1.0KHz~11.0KHz0.1KHz
    PULSE100Hz1~100000cycles1cyc_______

    Output voltage: 1~11 Vp-p (zero base waveform);
    Amplitude accuracy: ±(10% +0.5V);
    Maximum load: >100 KΩ;
    Duty Cycle: 50%.

    1KHz
    10KHz
    LOOP24V±10%

    Maximum current: 25 mA
    Short circuit protected

    Other feature:

    l Temperature Coefficient: 0.1 times the applicable accuracy specification per degree ℃for 5℃ to 18℃ and 28℃ to 50℃.

    l Maximum voltage between any output terminal and earth: 30Vpk

    Maximum output current: Approximately 25mA.
    General Specifications for Pressure

    FunctionReferenceRangeResolutionAccuracyRemark
    PRESSUREDetermined by pressure module_____Determined by pressure moduleDetermined by pressure moduleFor more detail, refer the pressure module about APM.