Sign In | Join Free | My himfr.com
Home > VICTOR Digital Multimeter >

Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

    Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers
     
    Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers
    • Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers
    • Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers
    • Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers
    • Buy cheap Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 from wholesalers

    Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

    Ask Lasest Price
    Brand Name : VICTOR
    Model Number : VICTOR 79
    Certification : CE
    Price : USD200/pc
    Payment Terms : T/T, Western Union, L/C, Paypal
    Supply Ability : 3000pcs available
    Delivery Time : 5 to 30 days
    • Product Details
    • Company Profile

    Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

    VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD RSKEJTNB Cu50 Pt100


    Specifications

    All the speculations apply to +18℃to +28℃, 10% to 70%RH unless stated otherwise.

    All speculations assume a 5- minute warm- up period.

    Standard speculation is valid for one year.


    DC Voltage Measurement

    Range(DC V)ResolutionAccuracy,+( % of reading +counts)
    4.000V0.001V0.2%+4
    40.00V0.01V0.2%+4
    400.0V0.1V0.2%+4

    Measuring Impedance:10 MΩ(nominal),<100pF

    Common mode rejection ratio: 50Hz or 60Hz > 100dB

    Normal mode rejection ratio: 50Hz or 60Hz > 45dB

    Overvoltage protection: 600Vp-p


    DC mV Measurement

    Range(DC mV)ResolutionAccuracy,+( %reading +counts)
    40.00mV0.01 mV0.5%+6
    400.0mV0.1 mV0.2%+4

    Measuring Impedance: 10 MΩ(nominal)

    Overvoltage protection: 600Vp-p


    TC Measurement

    Range(type)Set RangeResolutionAccuracy+(%reading +counts)
    R-40~1760℃1℃

    0.5%+3(≤100℃)

    0.5%+2(>100℃)

    S-20~1760℃1℃

    0.5%+3(≤100℃)

    0.5%+2(>100℃)

    B400~1800℃1℃

    0.5%+3(≤600℃)

    0.5%+2(>600℃)

    E-200~500℃1℃

    0.5%+2(≤-100℃)

    0.5%+1(>-100℃)

    K-200~950℃1℃

    0.5%+2(≤-100℃)

    0.5%+1(>-100℃)

    J-200~700℃1℃

    0.5%+2(≤-100℃)

    0.5%+1(>-100℃)

    T-200~400℃1℃

    0.5%+2(≤-100℃)

    0.5%+1(>-100℃)

    N-200~1000℃1℃

    0.5%+2(≤-100℃)

    0.5%+1(>-100℃)

    By using ITS-90 temperature scale

    Note: The accuracy does not include the error of internal temperature compensation caused by a sensor. The range of the internal temperature compensation sensor is + 2℃.


    AC Voltage Measurement

    Range(ACV)Resolution

    Accuracy,+( %reading +counts)

    40~400Hz

    400.0mV0.1mV1.0%+4
    4.000V0.001V0.5%+4
    40.00V0.01V0.5%+4
    400.0V0.1V0.5%+4

    Specifications are valid from 5% to 100% of amplitude range

    400mV is only confined to manual range

    AC conversion: average value

    Measuring Impedance: 10 MΩ(nominal),<100pF

    Common mode rejection ratio: 50Hz or 60Hz > 100dB

    Overvoltage protection: 600Vp-p

    DC Current Measurement

    Range(DC mA)ResolutionAccuracy,+( %reading +counts)
    40.00mA0.01 mA0.2%+4
    400.0 mA0.1 mA0.2%+4

    Overload protection: 0.5A,250V fast-blow fuse

    Measuring Impedance: 1Ω


    AC Current Measurement

    Range(AC mA)Resolution

    Accuracy,+( %reading +counts)

    40~400Hz

    40.00mA0.01 mA0.5%+4
    400.0 mA0.1 mA0.5%+4

    Specifications are valid from 5% to 100% of amplitude range

    Overload protection: 0.5A,250V fast-blow fuse

    Measuring Impedance: 1Ω


    Resistance Measurement

    RangeResolutionAccuracy,+( %reading +counts)
    400.0Ω0.1Ω0.2%+4
    4.000kΩ0.001kΩ0.2%+4
    40.00kΩ0.01kΩ0.2%+4
    400.0kΩ0.1kΩ0.2%+4
    4.000MΩ0.001 MΩ0.5%+4
    40.00 MΩ0.01 MΩ1%+4

    Open circuit voltage:0.4v

    Guide lead resistance is excluded in the accuracy

    Overvoltage protection: 600Vp-p


    RTD Measurement

    Range(type)Input RangeResolutionAccuracy,+( %reading +counts)
    Pt100-200~700℃1℃0.5%+2
    Cu50-50~150℃1℃0.5%+4

    By using Pt100-385 temperature scale

    Measuring current 1 mA

    Note: attached lead resistance is excluded


    Frequency Count Accuracy

    RangeResolutionAccuracy,+( %reading +counts)
    50.00Hz0.01Hz0.1%+3
    500.0Hz0.1Hz0.1%+3
    5.000KHz1Hz0.1%+3
    50.00KHz0.01KHz0.1%+3
    100.0KHz0.1KHz0.1%+3
    Display updates 3 times/second (at >10Hz)

    Diode Test and Continuity Test

    Diode test indication:

    Displays voltage drop across device, open circuit voltage: 1.1v-1.6v; short circuit current:<0.2 mA(typical value). Accuracy+ (2%reading +1count)

    Continuity test indication:

    Continuous audible tone for test resistance<50

    Open circuit voltage: <0.45v

    Short circuit current:130μA typical

    Overload protection: 600V(peak)

    Technical Data


    ProjectVICTOR 77VICTOR 78VICTOR 79
    MeasurementDC voltageRange±51V±400V±400V
    The highest
    resolution
    10mV0.01mV0.01mV
    Basic accuracy0.5%0.2%0.2%
    AC voltageRange`510V400V400V
    The highest
    resolution
    100mV0.1mV0.1mV
    Basic accuracy1.5%0.5%0.5%
    ResistanceRange5kΩ40MΩ40MΩ
    The highest
    resolution
    0.1Ω0.1Ω
    Basic accuracy0.5%0.2%0.2%
    DC currentRange±22mA±400mA±400mA
    The highest
    resolution
    1uA10uA10uA
    Basic accuracy0.2%0.2%0.2%
    AC currentRangeN/A400mA400mA
    The highest
    resolution
    10uA10uA
    Basic accuracy0.5%0.5%
    ThermocoupleRangeN/AN/AR,S,B,E,K,J,T,N
    The highest
    resolution
    1°C
    Basic accuracy0.5%
    RTDRangeN/AN/ACu50,Pt100
    The highest
    resolution
    1°C
    Basic accuracy0.5%
    CAPRangeN/AN/AN/A
    The highest
    resolution
    Basic accuracy
    FrequencyN/A10Hz~100kHz10Hz~100kHz
    Diode test
    Continuity beeper
    Data hold
    Relative value measurementN/A
    SourceDC voltageRangeN/A-50.0mV~550.0mV
    -0.500V~5.500V
    -10.00mV~110.00mV
    -0.5000V~5.5000V
    Resolution0.1mV,1mV0.01mV,0.1mV
    Basic accuracy0.2%0.2%
    ResistanceRangeN/AN/A0~400.0Ω
    Resolution0.1Ω
    Basic accuracy0.2%
    DC currentRange22mA22mA22mA
    Resolution0.001mA0.01mA0.001mA
    Basic accuracy0.2%0.2%0.2%
    Simulating transmitter
    25%,100%Step output
    Automatic rampN/A
    Automatic stepN/A
    Display current and % of span
    Loop power24V15V15V
    FrequencyN/A1.0Hz~11.0kHz1.0Hz~11.0kHz
    ThermocoupleN/AN/AR,S,B,E,K,J,T,N
    RTDN/AN/ACu50,Pt100
    Loop detectionThe 24V loop power supply and measuring the currentN/AN/A
    Built in 250 Ω
    HART loop resistance
    N/AN/A
    Power Supply2×1.5V AA Alkaline battery4×1.5V AAA Alkaline battery4×1.5V AAA Alkaline battery
    Auto Power-off
    BacklightN/A
    SafetyCAT Ⅳ 600V,
    Pollution degree 2
    CAT Ⅲ 600V ,
    Pollution degree 2
    CAT Ⅲ 600V,
    Pollution degree 2
    Size180×90×52205×95×42205×95×42
    WeightAbout 400gAbout 500gAbout 500g
    AccessoriesTest line, manual,fuseTest line, manual,fuseTest line, manual,fuse
    Standard Quantity Per Carton10pcs10pcs10pcs
    Standard Carton Measurement395mm*385mm*260mm395mm*385mm*260mm395mm*385mm*260mm
    Standard Carton Cross Weight8.8Kg9.8Kg10.2Kg

    Quality Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: XI'AN BEICHENG ELECTRONICS CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)